Poly- and Perfluoroalkyl Substances in Runoff Water and Wastewater Sampled at a Firefighter Training Area - Anses - Agence nationale de sécurité sanitaire de l’alimentation, de l’environnement et du travail Accéder directement au contenu
Article Dans Une Revue Archives of Environmental Contamination and Toxicology Année : 2019

Poly- and Perfluoroalkyl Substances in Runoff Water and Wastewater Sampled at a Firefighter Training Area

Résumé

Per- and polyfluoroalkyl substances (PFASs) are key ingredients of firefighting foams designed to suppress fires involving flammable and combustible liquids. Such foams are used by firefighters during fire training at dedicated sites. Because PFASs are very persistent chemicals, substantial soil and groundwater contamination has been observed in the vicinity of firefighter training areas. However, very few data are available on PFAS contamination of wastewater and runoff water on such sites. The purpose of this study was to evaluate the occurrence of more than 50 PFASs in 43 water samples (effluent from a wastewater treatment plant (WWTP), lagoon, runoff water, and wastewater drained from firefighter training areas) collected from a large firefighter training site, using target and suspect screening. A comparison of the PFAS classes analyzed revealed the overwhelming contribution of fluorotelomers. This indicates that the PFAS emission from the use of firefighting foams cannot be monitored only by measuring perfluoroalkyl acids. Based on the PFAS concentrations measured through target screening, the PFAS mass discharged into the river receiving WWTP effluent and the lagoon was on average 387 ± 183 kg and 56 ± 15 kg per year respectively. Due to the unavailability of standards, it was impossible to take into account the PFASs detected with suspect screening. The present study emphasizes that, above and beyond soil and groundwater contamination, such sites also contribute to the PFAS burden of surface water.

Domaines

Chimie organique
Fichier non déposé

Dates et versions

anses-03457450 , version 1 (30-11-2021)

Identifiants

Citer

Xavier Dauchy, Virginie Boiteux, Adeline Colin, Cristina Bach, Christophe Rosin, et al.. Poly- and Perfluoroalkyl Substances in Runoff Water and Wastewater Sampled at a Firefighter Training Area. Archives of Environmental Contamination and Toxicology, 2019, 76 (2), pp.206-215. ⟨10.1007/s00244-018-0585-z⟩. ⟨anses-03457450⟩

Collections

ANSES
23 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More