Simultaneous Detection of 14 Microcystin Congeners from Tissue Samples Using UPLC- ESI-MS/MS and Two Different Deuterated Synthetic Microcystins as Internal Standards - Anses - Agence nationale de sécurité sanitaire de l’alimentation, de l’environnement et du travail Access content directly
Journal Articles Toxins Year : 2019

Simultaneous Detection of 14 Microcystin Congeners from Tissue Samples Using UPLC- ESI-MS/MS and Two Different Deuterated Synthetic Microcystins as Internal Standards

Stefan Altaner
  • Function : Author
Jonathan Puddick
  • Function : Author
Valérie Fessard
  • Function : Author
  • PersonId : 881770
Daniel Feurstein
  • Function : Author
Ivan Zemskov
  • Function : Author
Valentin Wittmann
  • Function : Author
Daniel R Dietrich
  • Function : Author

Abstract

Cyanobacterial microcystins (MCs), potent serine/threonine-phosphatase inhibitors, pose an increasing threat to humans. Current detection methods are optimised for water matrices with only a few MC congeners simultaneously detected. However, as MC congeners are known to differ in their toxicity, methods are needed that simultaneously quantify the congeners present, thus allowing for summary hazard and risk assessment. Moreover, detection of MCs should be expanded to complex matrices, e.g., blood and tissue samples, to verify in situ MC concentrations, thus providing for improved exposure assessment and hazard interpretation. To achieve this, we applied two synthetic deuterated MC standards and optimised the tissue extraction protocol for the simultaneous detection of 14 MC congeners in a single ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) run. This procedure was validated using plasma and liver homogenates of mice (male and female) spiked with deuterated MC standards. For proof of concept, tissue and plasma samples from mice i.p. injected with MC-LR and MC-LF were analysed. While MC-LF was detected in all tissue samples of both sexes, detection of MC-LR was restricted to liver samples of male mice, suggesting different toxicokinetics in males, e.g., transport, conjugation or protein binding. Thus, deconjugation/-proteinisation steps should be employed to improve detection of bound MC. Key Contribution: The use of deuterated microcystin standards and an improved extraction procedure using UPLC-MS/MS analytics, provides for the simultaneous detection of fourteen microcystin congeners. Thus, it allows more accurate quantitation of total microcystin load of a given sample in complex matrices like blood or tissue, and therefore better hazard interpretation.
Fichier principal
Vignette du fichier
altaner1.pdf (966.04 Ko) Télécharger le fichier
Origin : Publisher files allowed on an open archive
Loading...

Dates and versions

anses-02347418 , version 1 (05-11-2019)

Licence

Attribution

Identifiers

Cite

Stefan Altaner, Jonathan Puddick, Valérie Fessard, Daniel Feurstein, Ivan Zemskov, et al.. Simultaneous Detection of 14 Microcystin Congeners from Tissue Samples Using UPLC- ESI-MS/MS and Two Different Deuterated Synthetic Microcystins as Internal Standards. Toxins, 2019, 11 (7), pp.388. ⟨10.3390/toxins11070388⟩. ⟨anses-02347418⟩

Collections

ANSES
302 View
207 Download

Altmetric

Share

Gmail Facebook Twitter LinkedIn More